Ceiling Cassette
Inverter
Provides better and more even cooling while saving space
4.0 hp (3 TR) / 7.0 hp (5 TR)
KOLIN Ceiling Cassette Type Inverter |
Model |
Horse Power (HP) |
SRP |
---|---|---|
KLM-IS40-3D1M | 4.0 HP (3 TONS) | 108,670 Php |
KLM-IS70-3D3M | 7.0 HP (5 TONS) | 155,055 Php |
Ceiling Cassette at its Finest!
Kolin's ceiling cassette is embedded with a high powered compressor that efficiently maximizes the cooling performance in an entire room with a lifespan that will surely last for years. Kolin also made its product more user-friendly and increased its safety measures by developing a feature that is programmed to automatically recognize any minor and major error by displaying its corresponding error codes that will notify the user immediately. Kolin's ceiling cassette was specially manufactured and produced to provide a maximum performance to help you satisfy your cooling needs. Thanks to inverter technology, this air conditioner removes passively any power waste produced by the compressor, making it more energy-efficient so you won't have to worry about spending too much!
Built-In Water Drain Pump
It has a built-in water drain pump that collects water excess during cooling operation.
Self-Diagnostic Error
The self Diagnostic Error feature enables you to scan your AC unit in a short period of time and will express any troubles that it identifies through error codes that will appear on the display board.
Note: Product features, specifications, and prices are subject to change without prior notice.
Model |
|
KLM-IS40-3D1M |
|
Power Supply | 1 PH / 230 V / 60 Hz |
Nominal Capacity | 4.0 hp (3 TR) |
Cooling Capacity | 11,495 - 37,980 kJ/h |
Rated Current | 5.1 -17.2 A |
Rated Power | 1,200 - 3,770 W |
EER | 9.6 - 10.1 kJ/hW |
Refrigerant (type/charge) | R-410A / 2,800 g |
Indoor Unit | |
Airflow (Hi/Mi/Lo) | 2,000 / 1,700 / 1,450 m³/h |
Sound Level (Hi/Mi/Lo) | 54.4 / 48.4 / 46 dB(A) |
Front Panel Dimension (WxDxH) | 950 x 950 x 55 mm |
Unit Dimension (WxDxH) | 840 x 840 x 245 mm |
Packaging Dimension (WxDxH) | 900 x 900 x 257 mm |
Unit Weight (Net/Gross) | 25.0 / 30.0 kg |
Outdoor Unit | |
Unit Dimension (WxDxH) | 946 x 410 x 810 mm |
Packaging Dimension (WxDxH) | 1090 x 500 x 875 mm |
Unit Weight (Net/Gross) | 69.0 / 75.0 kg |
Copper Tube Size | |
Low Side | Ø 5/8 " |
High Side | Ø 3/8 " |
Maximum Pipe Distance Between Indoor and Outdoor | |
Height | 10 m |
Length | 30 m |
Circuit Breaker | 40 A |
|
|
Model |
|
KLM-IS70-3D3M |
|
Power Supply | 3 PH / 230 V / 60 Hz |
Nominal Capacity | 7.0 hp / 5 TR |
Cooling Capacity | 19,100 - 63,523 kJ/h |
Rated Current | 5.5 - 18.2 A |
Rated Power | 1,950 - 5,990 W |
EER | 9.8 - 10.6 kJ/hW |
Refrigerant (Type/Charge) | R-410A / 4,050 g |
Indoor Unit | |
Airflow (Hi/Mi/Lo) | 1756 / 1428 / 1309 m³/h |
Sound Level (Hi/Mi/Lo) | 50.3 / 46.6 / 42.3 dB(A) |
Front Panel Dimension (WxDxH) | 950 x 950 x 55 mm |
Unit Dimension (WxDxH) | 840 x 840 x 287 mm |
Packaging Dimension (WxDxH) | 900 x 900 x 292 mm |
Unit Weight (Net/Gross) | 29.0 / 33.3 kg |
Outdoor Unit | |
Unit Dimension (WxDxH) | 952 x 415 x 1333 mm |
Packaging Dimension (WxDxH) | 1095 x 495 x 1400 mm |
Unit Weight (Net/Gross) | 104 / 116 kg |
Copper Tube Size | |
Low Side | Ø 3/4" |
High Side | Ø 3/8" |
Maximum Pipe Distance Between Indoor and Outdoor | |
Height | 10 m |
Length | 30 m |
Circuit Breaker | 40 A / 3 PH |
Note: Product features, specifications, and prices are subject to change without prior notice.
|